ES-8700JCLF Metro Cluster 2019-01-08T10:37:18+00:00

ES-8700JCLF Metro Cluster with Open-E Jovian DSS and ZFS

ES-8700JCLF Metro Cluster - Overview

  • Shared Storage Metro Cluster with two nodes and mirrored FC JBODs
  • Open-E JovianDSS active/active cluster software
  • NFS, CIFS, iSCSI and optional Fibre Channel
  • ZFS file system on Linux kernel for maximum data integrity and protection against "stealth errors" with check sum and disk scrubbing
  • 2 x 1 Gbit Ethernet onboard for inter-node connect
  • 2 x 10 Gbit Ethernet for clients (optional more, also 25 and 40 Gbit)
  • 16 Gbit FC HBAs for the JBODs
  • Shared Storage FC JBOD: 24 3.5" slots, 4 U (alternatively: 12, 16 x 3.5", 24 x 2.5")
  • for SAS/Nearline disks, SSD, 16 Gbit FC to the nodes
  • Find your ideal configuration with our JovianDSS Configurator!

ES-8700JCLF Metro Cluster - fully customized for your business

We will be pleased to send you a non-binding offer by e-mail - for inquiries on working days until 4 pm on the same day!

You have questions about the configuration?

Dann rufen Sie uns an:
+49 (0) 711 - 70 70 91 70

Product information

ES-8700 JDSS cluster with ZFS file system offer extremely high data availability. Being a shared storage solution this used to be restricted to one location only. With the new metro cluster version this restriction does not exist any longer: the disks are located at two sites and then mirrored across the locations. Thus also the complete failure of one site does not affect data availability at all.
The distance between the two sites of the metro cluster are only limited by Fibre Channel and network restrictions. As cable connection only two 1 Gbit Ethernet lines are required for the communication between the cluster nodes and two 16 Gbit Fibre Channel lines to connect the nodes to the JBOD on the other side. In this configuration any single node can be shut down, e.g. for maintenance reasons, without breaking the disk mirrors.
The Cluster supports iSCSI as well as NFS and CIFS access.
Additionally the data can be asynchronously replicated to a second site, over the network. On the other side only a single ES-8700 Jovian DSS system is needed.

Model overview

system architecture X10 single socket (XST)
  • Intel E5-1620v4 processor on X10 Board single socket
  • 32 GB DDR 4 RAM, optional up to 512 GB
  • 2 Ethernet ports (1 Gbit), 1 IPMI port
pdf offer
system architecture X10 dual socket (XDT)
  • Intel E5-2623v4 processor on X10 Board, opt. dual processor
  • 32 GB DDR4 RAM, optional up to 1024 GB
  • 2 Ethernet ports (10 Gbit RJ45), 1 IPMI port
pdf offer
system architecture X11 dual socket (DA)
  • Intel XEON 4110 processor on X11 Board, opt. dual processor
  • 32 GB DDR4 RAM, optional up to 1024 GB
  • 2 Ethernet ports (10 Gbit RJ45), 1 IPMI port
pdf offer
optional ports
  • more 10/25/40 Gbit iSCSI ports
  • SAS expansion ports for JBODs
installed software
  • Open-E Jovian DSS software
  • with ZFS self healing file system
  • with mirrors: net capacity licensed
Jovian DSS features
  • OS on SATA DOM or on 2 mirrored SSD boot disks (in additional slots)
  • maximum data integrity and protection against "Stealth Errors" (with checksums and scrubbing)
  • disk redundancy with Mirror, raidz, raidz2, raidz3 (equivalent to RAID 1, 5, 6 and triple parity)
  • optional SSDs for I/O acceleration during write operations (write log “ZIL“) and read cache (“L2ARC“)
  • practically unlimited snapshots without loss of performance
  • iSCSI, CIFS/SMB and NFS volumes, opt. FC for VMware and Linux
  • Thin- and Overprovisioning for best use of disk capacity
  • LZ4 data compression and inline deduplication
  • asynchronous replication to a remote system with Offsite Data Protection Service (ODPS)
  • intuitive web GUI for simple management
  • optional: shared storage cluster or metro cluster
monitoring / management
  • integrated web based RAID and virtualization manager
  • email notification
  • hardware management over IPMI 2.0 with KVM support