Infortrend SAS/SAS

EonStor DS SAS RAID, 16 disks
Infortrend EonStor DS SAS RAID systems are used as direct attached storage, over a SAS (Serial Attached SCSI) connection. In the server the RAID partitions can be seen like normal SCSI disks - of course with much higher capacity.
The advantage: SAS and SATA disks can be mixed within the same RAID box, in order to offer high performance disk capacity for database applications together with low cost SATA capacity e.g. for data archiving.
The system can be expanded over a SAS port.
The new series based on the faster G7 controller offer nearly twice the i/o performance compared to previous versions.
Some systems optionally offer thin provisioning (cf. datasheet).
- Express Exchange Service and On Site Service available for all RAID systems
Price List
| Product | Description | Price (excl. VAT) | |
|---|---|---|---|
| Infortrend EonStor DS 6 Gbit SAS RAID, single controller, 2 SAS ports | |||
| ESDS-S04S-G2240 | Infortrend EonStor DS 6 Gbit SAS/SAS RAID with RAID 6, single controller, ASIC667, 19 inch, 1 U, 2x SAS (4x6 Gbit) to host, 2 GB cache, SAS cable, slide rails included, 4 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
1760 € | |
| ESDS-S12S-G2240 | Infortrend EonStor DS 6 Gbit SAS/SAS RAID with RAID 6, single controller, ASIC667, 19 inch, 2 U, 2x SAS (4x6 Gbit) to host, 2 GB cache, SAS cable, expandable with SAS port (max. 84 disks), slide rails included, 12 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
4290 € | |
| ESDS-S16S-G2240 | As above, but 16 disks, 3 U, expandable to 112 disks | 5590 € | |
| ESDS-S24S-G2240 | As above, but 24 disks, 4 U, expandable to 104 disks | 8090 € | |
| Infortrend EonStor DS 6 Gbit SAS RAID, dual controller, 2 SAS ports each | |||
| ESDS-S12S-R2240 | Infortrend EonStor DS 6 Gbit SAS/SAS RAID with RAID 6, dual controller, ASIC667, 19 inch, 2 U, 2x SAS (4x6 Gbit) to host, 2 GB cache, SAS cable, expandable with SAS port (max. 84 disks), slide rails included, 12 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
6390 € | |
| ESDS-S16S-R2240 | As above, but 16 disks, 3 U, expandable to 112 disks | 7690 € | |
| Infortrend EonStor DS 6 Gbit SAS RAID, single controller, 4 SAS ports | |||
| ESDS-S12S-G2240-4 | Infortrend EonStor DS 6 Gbit SAS/SAS RAID with RAID 6, single controller, ASIC667, 19 inch, 2 U, 4x SAS (4x6 Gbit each) to host, 2 GB cache, SAS cable, expandable with SAS port (max. 84 disks), slide rails included, 12 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
4490 € | |
| ESDS-S16S-G2240-4 | As above, but 16 disks, 3 U, expandable to 112 disks | 5890 € | |
| ESDS-S24S-G2240-4 | As above, but 24 disks, 4 U, expandable to 104 disks | 8290 € | |
| Infortrend EonStor DS 6 Gbit SAS RAID, dual controller, 4 SAS ports each | |||
| ESDS-S12S-R2240-4 | Infortrend EonStor DS 6 Gbit SAS/SAS RAID with RAID 6, dual controller, ASIC400, 19 inch, 2 U, 4x SAS (4x6 Gbit each) to host, 2 GB cache, SAS cable, expandable with SAS port (max. 84 disks), slide rails included, 12 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
6890 € | |
| ESDS-S16S-R2240-4 | As above, but 16 disks, 3 U, expandable to 112 disks | 8290 € | |
| Infortrend EonStor DS G7 series | |||
| ESDS-S16S-G2250 | Infortrend EonStor DS 6 Gbit SAS/SAS RAID with RAID 6, single controller, G7 series, 19 inch, 3 U, 4x SAS (4x6 Gbit each) to host, 4 GB cache, SAS cable, expandable with SAS port (max. 240 disks), slide rails included, 16 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
6790 € | |
| ESDS-S16S-R2250 | as above, but dual active/active controller | 9790 € | |
| Infortrend EonStor DS SAS expansion system, single controller | |||
| ESDS-S12S-J2000-G | Infortrend EonStor DS single controller 6 Gbit SAS expansion box, 19 inch, 2 U, SAS (4x6 Gbit) port, SAS cable, slide rails included, 12 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
3690 € | |
| ESDS-S16S-J2000-S | As above, but 16 disks, 3 U | 4690 € | |
| Infortrend EonStor DS SAS expansion system, dual controller | |||
| ESDS-S12S-J2000-R | Infortrend EonStor DS dual controller 6 Gbit SAS expansion box, 19 inch, 2 U, SAS (4x6 Gbit) port, SAS cable, slide rails included, 12 x 1 TB Nearline SAS disk, 7,200 rpm (SATA disks up to 3 TB, SAS up to 600 GB/15K available) |
4090 € | |
| ESDS-S16S-J2000-R | As above, but 16 disks, 3 U | 5090 € | |
| Options | |||
| ARC-1880IX-MEM4 | 4 GB cache instead of standard (2 required for dual controller systems) | 190 € | |
| ESO9373CCBM | Battery backup + flash for Infortrend EonStor, Infortrend EonStor DS, single controller, ASIC667 G6 | 250 € | |
| ESO9373CFBM | Flash Module for dual controller Infortrend EonStor, Infortrend EonStor DS, ASIC667 G6 (2 required) | 110 € | |
| ESO82-OPTDS | Infortrend EonStor DS lizence expansion for 264 snapshots (max. 4096) and 32 local replications per volume | 2090 € | |
| Software options (availability cf. datasheet) | |||
| ESO82-OPTTPRDS | Thin Provisioning for Infortrend EonStor DS Systeme (only supported by some systems) | upon request | |
| host bus adapter | |||
| LSI-SAS3801E | LSI LOGIC SAS adapter,PCI Express x8, 2x MiniSAS (8088) external (4x 3 Gbit each) | 190 € | |
| LSI-SAS3801X | As above, but 64 bit PCI-X | 200 € | |
Features
- 4 to 24 SAS, SSD or SATA disks
- up to 48 TB (with 2 TB disks)
- SAS: up to 600 GB per disk
- all systems except for 4-bay expandable with SAS expansion port up to 84-104 disks (cf. product description in price list)
- 3 Gbit SAS with ASIC400, 6 Gbit with ASIC667 technology on Infortrend Controller
- OS independent
- 2 GB cache per controller (opt. 4 GB)
- battery backup (option with single conroller, otherwise included)
- 2 or 4 SAS host interfaces (4x3 or 4x6 Gbit/s) per controller
- RAID Level 0, 1, 0+1, 3, 5, 6, 10, 30, 50, 60, NRAID
- RAID and volume expansion on-the-fly
- 64 snapshots per volume (max. 1024), optional more
- local volume copy (16 pairs, optional more)
- some systems with optional thin provisioning
- local and global hot spare disks
- redundant PSU and fans
- monitoring of fan rotation, temperature and voltage
- RAID management over internal WEB server (Ethernet port)
- 3 years warranty
New: G7 Series, with still faster controllers
- 6 Gbit SAS
- expandable up to 240 disks
- 4 GB cache, optional 8 GB
- all other features as above (no thin provisioning)
Details
| model | Infortrend EonStor DS SAS RAID | |||
|---|---|---|---|---|
| single controller G6 | ES-S04S-G2240 | ESDS-S12S-G2240(-4) | ESDS-S16S-G2240(-4) | ESDS-S24S-G2240(-4) |
| redundant active/active controller G6 | n.a. | ESDS-S12S-R2240(-4) | ESDS-S16S-R2240(-4) | n.a. |
| single controller G7 | n.a. | n.a. | ESDS-S16S-G2250 | n.a. |
| redundant active/active controller G7 | n.a. | n.a. | ESDS-S16S-R2250 | n.a. |
| number of disks | 4 | 12 | 16 | 24 |
| max. expandable | -- | 84 | 112 | 104 |
| disk interface | 6 Gbit SAS | |||
| host interface | 2 x 6 Gbit SAS channels per controller, -G2240-4 and -R2240-4: 4 channels | |||
| controller | 2240 series: Infortrend G6 (ASIC 667) 2250 series: Infortrend G7 | |||
| RAID level | 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID | |||
| cache | G6: 2 GB per controller, optional up to 4 GB G7: 4 GB per controller, optional up to 8 GB | |||
| battery backup for cache | included with redundant controllers, otherwise optional | |||
| RAID features | • multiple array configuration • hot-spare drives (local or global) • automatic replacement of hot-spare drives and • background rebuild • online capacity expansion • intelligent drive handling • disk cloning • all RAID configuration saved on the disks | |||
| RAID management | • firmware embedded Web browser based RAID manager • web browser based RAID Manager (SANwatch, embedded RAIDwatch), 10/100 Mbit Ethernet Port • RAID Manager also over serial RS-232 port, telnet, ssh and LCD display | |||
| virtualization features | • up to 64 snapshots per volume (up to 1024 in total), optional 256 (4048) • local volume replication (up to 16 replication pairs, optional 32) • thin provisioning (optional only with G6 Series) | |||
| monitoring / notification | • embedded Web browser based RAID manager, • monitoring over web browser based RAID manager • system status over LCD, LED and beeper • email notification / SNMP | |||
| operating system | transparent | |||
| PSU | 1x 200 Watt with PFC | 2x 350 Watt with PFC (redundant) | 2x 530 Watt with PFC (redundant) | 3x 405 Watt with PFC (redundant) |
| rackmount size | 1 U | 2 U | 3 U | 4 U |
| temperature | operating: 0 – 40°C | |||


